Wykaz Projektów
- Opracowanie poradnika dla pracodawców dla potrzeb oceny ryzyka zawodowego związanego ze sztucznym promieniowaniem optycznym uwzględniającego wymagania dyrektywy 2006/25/WE.
- The ergonomic indirect lighting with modern light sources at workstations with display screens.
- Badanie wpływu olśnienia na zdolność spostrzegania u osób starszych dla potrzeb określania ujednoliconego wskaźnika ograniczenia olśnienia (UGR) przy projektowaniu oświetlenia pomieszczeń pracy
- Study of the effect of glare on the ability of perception among elderly for the purpose of determining unified glare rating (UGR) when designing the lighting in working rooms.
- Estimation of threat of the non-laser optical radiation emitted through artificial radiation sources in workstations
- Development of employer`s guidebook for the purposes of risk assessment associated with artificial optical radiation taking into account the requirements of 2006/25/WE directive.
- System ergonomicznego oświetlenia pośredniego z nowoczesnymi źródłami światła na stanowiskach pracy z monitorami ekranowymi
- Ocena zagrożenia nielaserowym promieniowaniem optycznym emitowanym przez sztuczne źródła na stanowiskach pracy.
Streszczenie
Study of the effect of glare on the ability of perception among elderly for the purpose of determining unified glare rating (UGR) when designing the lighting in working rooms.
Kierownik projektu: Agnieszka Wolska Ph.D. (Eng.)
Streszczenie projektu:
The aim of the project was to develop test methods for testing the effect of glare on the ability of perception and degree of glare sensation among the elderly and to develop recommendations of preferred unified glare rating values (UGR) when designing lighting for the elderly. To achieve this purpose a control room was built and a method of experimental research on the influence of discomfort glare on perception among elderly 50+ was developed. To measure the ratio of glare UGR a portable system for measuring the luminance LMK Mobile Advanced Imaging Photometer (photometer LMK) was purchased with LMK LabSoft software, and a method measuring the UGR using the photometer was developed. A method testing the effect of glare on the ability perception was developed using a CCD calibrated camera to measure the luminance distribution that was verified in the pilot studies. Next, a proper study was carried in a group of 65 people: 33 from the group of 50+ and 32 people from the control group (aged 19-34 years) for two modeled conditions of discomfort glare at UGR = 19 and UGR = 22 designated computationally in DIALux program designed for lighting design. The results became a basis for development of training materials on test method of discomfort glare at workstation using a CCD camera calibrated to measure luminance, and recommendations for lighting designers on the choice of unified glare rating (UGR) when designing the lighting for the elderly.
Jednostka: Pracownia Promieniowania Optycznego
Okres realizacji: 01.01.2011 – 31.12.2013